Universal Tuya docsHomeSupported devicesRequest a deviceFAQChangelogArchitectureKnowledge baseCreditsSourcesContributing

Tuya manufacturer clusters 0xE000 / 0xE001 / 0xE002

SSOT from Google 0xE002 tuya sweep (P2267) + Z2M / ZHA / zigpy #823 / Zigbee-Peek-and-Poke / HA community.

Taxonomy (Z2M canonical)

ClusterIDZ2M nameRole
DP tunnel0xEF00manuSpecificTuyaMCU datapoints (not ZCL attrs)
Options / buttons0xE000manuSpecificTuya4Timing / button frames
Switch / power-on0xE001manuSpecificTuya3powerOnBehavior 0xD010, switchMode 0xD020, externalSwitchType 0xD030
Alarms / OEM radar0xE002manuSpecificTuya2Climate thresholds or Linptech radar attrs

Homey registers one Cluster class per ID → TuyaE002Cluster merges climate 0xD00* + Linptech 0xE00*.

0xE002 climate attributes (ManuSpecificTuya2)

AttrIDTypeNotes
alarmTemperatureMax0xD00Aint16Whole °C (Neo) or centi on some LCD
alarmTemperatureMin0xD00Bint16
alarmHumidityMax0xD00Dint16Z2M + Abysim; upstream ZHA wrongly used 0xD00C
alarmHumidityMaxLegacy0xD00Cint16RX alias only
alarmHumidityMin0xD00Eint16
alarmHumidity0xD00Fenum8ValueAlarm 0=min 1=max 2=off
alarmTemperature0xD006enum8Same ValueAlarm
beepSilence / unknown0xD010uint8Write 1 to mute beeper (HA #692449)

E002 does not carry live temperature/humidity — those use ZCL 0x0402 / 0x0405 (EP1 or virtual EP2 after magic 0xFFFE).

Runtime

Couples using E002 alarms

CoupleDriverNote
_TZ3000_qaaysllp+TS0201lcdtemphumidluxsensorNeo; EP2 measurements
_TZ3210_qkj7rujp+TS0201lcdtemphumidsensorHA beep-mute tip
Linptech t9ynfz4x+TS0225motion_sensor_radar_mmwaveSame cluster ID, radar attrs

Sources

← Knowledge base index · source