Universal Tuya docsHomeSupported devicesRequest a deviceFAQChangelogArchitectureKnowledge baseCreditsSourcesContributing

P3064 — family-by-family uplift (master, 2026-10-26)

Scope: every device family except IR blasters (separate track). Method: the coverage matrix (scripts/kb/z2m-coverage.js, master/stable/bastien) gave the "partial" couples; each gap was re-checked by hand against zigbee-herdsman-converters (local copy at commit 7462b54) and against the driver code itself, because most "missing DP" rows are artefacts: upstream DPs without a name (composite structs, ignored DPs such as [12, null, null]) never enter the DP catalogue.

Rules applied: exact manufacturer+product couples only, one source per couple, additive code, no 0xEF00 write at pairing, optional capabilities only after a real report (no empty tiles, no re-pair). New couples are not added in this batch (combo budget unchanged; master ~15496/15500).

Shared building blocks (new)

Results per family

FamilyReal gaps foundDone in P3064Parked / next
Plugs / energy metersMoes ZM7LT3 3-phase (_TZE284_cf4b5ktf): total power DP9, phase structs DP6-8, PF/frequency not decoded. TOQCB2-80 breakers: internal temperature DP131 unusedPer-couple map + 18-byte phase struct (sum until DP9 seen); TOQCB2-80 DP131 → measure_temperature (late)TOQCB2 protection thresholds DP102-119 as settings (needs compose settings); energy_meter_din lsanae15 DP3/4/17/21-24 (mostly unnamed upstream)
Switches / relaysSWS6TZ-WHITE (_TZE200_8eazvzo6) metering DP21-23 ignored in switch_wall_6gangLate measure_current/power/voltage on that couple onlyhbxadcl0 DP107 (unnamed upstream, ignorable)
DimmersMG-DIM02Z (_TZE284_da26abzz) in wall_dimmer_tuya uses DP141/142 + metering DP21-23; the V1 map (DP1/DP2, DP21 = backlight) misread itPer-couple TX/RX map (141 state, 142 brightness 0-1000), late metering, DPs blocked from dynamic discoveryKnob dimmer _TZE200_tgeqdjgk colour temperature DP107 (needs TX too)
Smoke / CO (safety)TS0601 couples in the IAS-based smoke_sensor driver had no datapoint path at allReceive-only DP path: TS0601_smoke_co (6ycgarab, aoah6bv8, 2841000000_6ycgarab) smoke DP1 / CO DP18 / battery DP15; PA-44Z (qvzsq3s2); GSKS-ZB (qcasmfan, + tamper DP4). alarm_co added late_TZE200_/_TZE204_6ycgarab: unsourced-kept (long-present, no upstream source, not pinned — same policy as d3m9v8p6/pwj6vuj9). _TZ3210_09hzmirw: EcoDim CCT bulb, removed from smoke_sensor in P3067 (now light_cct_ts0502b, baseline exemptions approvedBy dlnraja t561u/t555u delegated). _TZE284_6ycgarab: TS0601 only (Z2M, ZHA #4181, Tasmota) — single owner smoke_sensor, the TS0205-only smoke_sensor3 claim dropped (P3067)
Thermostats / TRVwindowcoverings_set "missing" rows are artefacts (valve position)—hpkusvom DP1 check
Covers"onoff" exposes are upstream backlight/limit switches; TS130F dropped rows are budget compaction, not gaps; cover_4 DP7 = work_state (Z2M ignores it). Real bug: curtain_motor wrote open/close time to DP101/102 at start and on settings — on AM43 (zah67ekd/icka1clh, Z2M TS0601_cover_4) DP102 is factory_reset, on libht6ua DP101 is motor_directionP3067: DP101/102 writes skipped for the AM43/tubular/Quoya family (settings kept, reverse unchanged)—
Buttons / keypadsWKE502Z _TZE200_rt5dklro: no ACK after arm (DP23), hub mode DP101 sent once forever though it resets at power cut, DP25/DP112 and options DP103-111 unmapped. _TZE200_kzm5w4iz vibration/contact sensor owned by button_emergency_sos (forbids alarm_contact). TS0041/TS0215A measure_voltage rowsP3067: ACK DP23 after DP27/28; hub mode per session + after DP25; DP25 → homealarm_state; DP112 → label setting; 7 non-blocking settings (DP103 0-180 s, DP104/105/106/107/110/111) written on change only, queued until the keypad wakes, volatile ones re-sent after DP25. kzm5w4iz moved to vibration_sensor (DP1 contact, DP3 battery, DP10 vibration; pinned)measure_voltage on battery buttons intentionally not added (battery % already derived from it)
LightsLED controllers 8fffc3kb / gt5al3bl DP61 (paint colour)—next batch
Climate / soilsoil AOYAN DP9 temperature unit; lb0fsvba DP6—settings only, low impact
Battery sensorsmany alarm_battery / measure_voltage expose rows—intentionally not added (SDK rule: no measure_battery + alarm_battery together)

P3067 catalogue decisions (2026-10-26)

CoupleDecisionSourceEffect on paired devices
_TZ3210_09hzmirw (4 casings) × TS0205/TS0601/SMD9300 in smoke_sensorremoved (parasite)Z2M tuya.ts TS0502B whiteLabel EcoDim ED-10032none: Homey keeps paired devices on their driver id; new pairings go to light_cct_ts0502b
_TZE200_6ycgarab, _TZE204_6ycgarab in smoke_sensorunsourced-keptnone upstreamnone
_TZE284_6ycgarab × TS0205 in smoke_sensor3dropped from smoke_sensor3 (double claim)Z2M TS0601_smoke_co, ZHA quirks #4181 (TS0601), Tasmota TZE284_6ycgarab.zb (TS0601)none; couple still in payload via smoke_sensor, baseline gate OK
_TZE200_7deq70b8 (2 casings each) × TS0601 in curtain_motormoved to switch_2gang (wrong class; pinned sacred-keep)Z2M tuya.ts TS0601_switch (same entry as _TZE200_nkjintbl), ZHA TuyaDoubleSwitchGP, blakadder ZY-US 2none (was never in the published payload under curtain_motor)
_TZE204_pxbjch8m × TS0601added to panel_switch_cover_tuya with its own exact profile (DP1 cover state, DP7 relay; DP8 motor direction left untouched, no write at pairing)Z2M tuya.ts TS0601_cover_with_1_switch_limitednew couple, nobody paired before
_TZE200_vawy74yh (co_sensor) and _TZE204/_TZE284_vawy74yh (climate_sensor) × TS0601moved to smoke_sensor (profile ssd01: DP1 0 = smoke, DP15 battery; pinned sacred-keep); co_sensor cartesian combos × TS0601_co/TS0212 removed with 4 baseline exemptions (approvedBy dlnraja t561u/t555u delegated); fingerprint hints → smoke_sensorZ2M moes.ts ZSS-HM-SSD01, ZHA tuya_smoke.py, blakadder Moes_ZSS-HM-SSD01, Hubitat Tuya Zigbee Smoke Detectornone to re-pair: co_sensor / climate_sensor map DP1 to alarm_smoke (added on first report) for this mfr instead of alarm_co / temperature
_TZE200_cxakecfo/ybsqljjg/4aijvczq/r5ksy7qo (2 casings) × TS0601ybsqljjg/4aijvczq/r5ksy7qo moved from climate_sensor to device_radiator_valve (pinned sacred-keep, hints + mfs_db → TRV); all 4 on the ME167 core profile + ME168 DPs (DP14/15 window, DP101/105 comfort/eco /10, DP103/104 boost) — DP15 no longer batteryZ2M avatto.ts ME168_AVATTO, Domoticz z4d TS0601-ME168none to re-pair: cxakecfo was on Profile A (DP3 read as setpoint, DP4 as temperature) and is corrected at runtime; the other 3 were never in the published payload. Budget 15500 cap: 5 cartesian artefacts displaced (ZB-CL01 × _tz3000 bulbs, BSEED socket in gateway_zigbee_bridge)

P3067 per-family completeness (t569u / t570u)

FamilySourced DPs mappedOptional ZCL fallbackLazy capabilities addedNew / moved driversLeft out (why)
Buttons / keypadsWKE502Z: 3, 23, 24, 25, 26-29, 101, 103-107, 110-112 (DP108/109 admin / user codes not exposed: secrets) ; kzm5w4iz 1, 3, 10not applicable (pure 0xEF00, nothing bound at pairing)none new (alarm_contact / alarm_vibration already in vibration_sensor)kzm5w4iz → vibration_sensormeasure_voltage on TS0041 / TS0215A (battery % already covers it)
LightsGL-SPI-206P: 1, 2, 3 (white only), 4, 61 RX+TX, 53, 101, 102, 103 ; MG-DIM02Z: 141-144, 146, 21-23 ; knob tgeqdjgk: 102, 103, 106, 107, 141ZCL onOff/level stay the primary path on TS050x bulbs (unchanged); SPI / MG / knob are pure 0xEF00none new (light_temperature on knob, measure_* on MG already lazy since P3064/P3066)noneSPI DP7 countdown, DP51 scene, DP52 music (need Flow actions, handed to P3065); knob DP111/112 actions, DP121/122/131/132 second light (needs a 2-light driver, budget); _TZE284_nvodulvi M9-zigbee-SL 8-gang scene switch sits on dimmer_wall_1gang (wrong family, needs its own driver: deferred, budget)
Soil / breaker (family 9)CS-201Z / ZG-303Z: 3, 5, 9 (guarded), 15, 106, 109 RX ; 102, 104 (/10), 105, 110, 111 kept as device-reported values (store) ; ZBN-DJ-63 _TZE204_lb0fsvba (moved lcdtemphumidsensor_3 → smart_breaker): 1, 6, 9, 16, 103 RX, 15 + 110 in storenone needed (pure 0xEF00)measure_temperature late on ZBN-DJ-63 (already a known capability, nothing for P3065)removed _TZE204_lb0fsvba+Excellux cartesian couples (exemption approvedBy)soil device-side calibration TX (would need a separate setting set, Homey offsets kept); ZBN-DJ-63 prepayment DP11-14, thresholds DP17/18, countdown/recover DP102-107 (settings/Flow, P3065) ; UFH rfpyqax9 DP101-108, sound ZY-N1 DP101, garage TS0603 DP12 : next
Lights — adaptive lighting (all lights)not DP-specific: CT via light_temperature, RGB-only via hue/sat white approximation, dimmer via dim (opt-in)ZCL colorTempPhysicalMin/Max mireds used when stored (ct_phys_min_mired / ct_phys_max_mired), else 2700–6500 Knone (settings adaptive_lighting default true, adaptive_brightness default false on 65 light drivers; global adaptive_lighting_global)nonestartup CT / power-on behaviour (ZCL 0x4010 startUpColorTemperatureMireds): deferred, per-couple support unverified ; lazy ZCL read of physical mireds: deferred
Energy estimates (all mains families)measure_power / measure_current / measure_voltage / power factor feed the precedence measured > calculated > learned > user > defaultnonenone (read-only energy_source label on 92 metered drivers; energy.approximation added to 48 unmetered on/off drivers)noneper-couple rated watts: table ready (couples), filled only when a reliable source states it

P3067 catalogue decisions, buttons / keypads

CoupleDecisionSourceEffect on paired devices
_TZE200_kzm5w4iz (4 casings) × TS0601moved from button_emergency_sos to vibration_sensor (pinned sacred-keep; hints + mfs_db → vibration_sensor)Z2M tuya.ts TS0601_vibration_sensor, ZHA quirk (DP1 contact, DP3 battery, DP10 vibration)none: paired devices stay on their driver; new pairings get contact + vibration

Credits

DP layouts: Koen Kanters and the zigbee-herdsman-converters contributors (tuya.ts models TS0601_smoke_co, PA-44Z, GSKS-ZB, moes.ts ZSS-HM-SSD01, MG-DIM02Z, SWS6TZ-WHITE, TOQCB2-80; moes.ts ZM7LT3). Facts only, own implementation, no code copied.

P3067 thermostat metering

CoupleDriverDPs (zhc tuya.ts)
_TZE200_snfdqllf AETZ01_ACair_conditioner_aetz01 (P3068, moved out of device_radiator_valve)116 W, 117 kWh (raw)
_TZE204_ilzkxrav TWC-R01device_radiator_valve11 W, 115 V, 116 A, 117 kWh (/10)
_TZE204_0hcjew5p TH-P1Zwall_thermostat11 W /10, 101 V /10, 102 A /1000, 107 kWh /10; DP101 no longer arms FCU

P3071 families 10-13 (master)

FamilyReal gapsDoneArtefacts (no change)
10 DIN / 3-phase metersdin_1 DP1 read as relay, DP6 struct unread; *-GT DP6/7/8 phase structs unreadper-couple decode in energy_meter_din / energy_meter_3phase (test p3071)DP17/18 alarm sets (zhc ignores them)
11 Smoke / gasnone—288WZ DP1 (enum, already 0 = alarm), gas_sensor_2 DP13 (zhc ignores)
12 Garage / valvesnone—TS0603 DP12 (zhc ignores), FK-BV05 windowcoverings_set (valve position)
13 UFH / sound / RCBOnone in code—Pro Line X10 DP101-110 already mapped; RCBO hkdl5fmv: hoch_din frame decoded (DP101-103/113), temperature DP105 via LateCapability, 0 manifest bytes (P3071c)