Reported by Umberto Maffii (Homey store suggestion): the Beca BAC-006AZB pairs but shows up as a plain switch, not a thermostat.
Identity (exact couples)
| mfr | pid | source |
|---|---|---|
_TZE204_dzuqwsyg | TS0601 | Z2M tuya.ts BAC-002-ALZB fingerprint + whitelabel Beca BAC-003; Z2M discussion #25308 (BAC-006AZB) |
_TZE200_dzuqwsyg | TS0601 | Z2M tuya.ts BAC-002-ALZB fingerprint |
Before: _TZE204_dzuqwsyg was on switch_1gang, _TZE200_dzuqwsyg on device_radiator_valve (TRV DP map). Both were the wrong device class, so they were moved (not duplicated). This is the one non-additive change, and it is deliberate. Script: tools/ci/p2970-bac002-wall-thermostat.js (idempotent, --check).
DP map (Z2M BAC-002-ALZB, in our own words)
| DP | meaning | Homey |
|---|---|---|
| 1 | power bool | onoff (off = system_mode off) |
| 2 | system mode enum 0 cool / 1 heat / 2 fan_only | thermostat_mode |
| 4 | preset bool, true = manual / false = auto | thermostat_programming ('0' manual) |
| 16 | setpoint, whole °C | target_temperature (TX not ×10; RX ≥100 read as tenths as a safety net) |
| 19 / 26 / 27 | max temp / deadzone / calibration | logged |
| 24 | room temp /10 | measure_temperature |
| 28 | fan 0 low / 1 medium / 2 high / 3 auto | fan_mode |
| 40 | child lock | child_lock |
| 101 | weekly schedule blob (36 bytes) | ignored: never TX'd as a bool (on TYBAC-006 DP101 is the manual bool) |
Existing users with the device on the old driver must re-pair it once so Homey picks the thermostat driver.