P2970 — Beca BAC-006AZB / BAC-002-ALZB on wall_thermostat

Reported by Umberto Maffii (Homey store suggestion): the Beca BAC-006AZB pairs but shows up as a plain switch, not a thermostat.

Identity (exact couples)

mfrpidsource
_TZE204_dzuqwsygTS0601Z2M tuya.ts BAC-002-ALZB fingerprint + whitelabel Beca BAC-003; Z2M discussion #25308 (BAC-006AZB)
_TZE200_dzuqwsygTS0601Z2M tuya.ts BAC-002-ALZB fingerprint

Before: _TZE204_dzuqwsyg was on switch_1gang, _TZE200_dzuqwsyg on device_radiator_valve (TRV DP map). Both were the wrong device class, so they were moved (not duplicated). This is the one non-additive change, and it is deliberate. Script: tools/ci/p2970-bac002-wall-thermostat.js (idempotent, --check).

DP map (Z2M BAC-002-ALZB, in our own words)

DPmeaningHomey
1power boolonoff (off = system_mode off)
2system mode enum 0 cool / 1 heat / 2 fan_onlythermostat_mode
4preset bool, true = manual / false = autothermostat_programming ('0' manual)
16setpoint, whole °Ctarget_temperature (TX not ×10; RX ≥100 read as tenths as a safety net)
19 / 26 / 27max temp / deadzone / calibrationlogged
24room temp /10measure_temperature
28fan 0 low / 1 medium / 2 high / 3 autofan_mode
40child lockchild_lock
101weekly schedule blob (36 bytes)ignored: never TX'd as a bool (on TYBAC-006 DP101 is the manual bool)

Existing users with the device on the old driver must re-pair it once so Homey picks the thermostat driver.