New drivers — 2026-10-11
Two lost-couple leads had no existing driver that fits, so each got its own driver on its own prep branch. That way the master worker can publish them one at a time, and if Athom rejects one, the other is not affected. The text below is our own write-up. Device facts come from the community sources credited for each driver.
valve_controller_5zone — AutomatOn AUT000069
- Couple (exact only):
_TZ3000_j0ktmul1+TS011F. It was previously onusb_dongle_tripleby mistake; it now has a curated removal from there. - Device: a mains-powered controller for 5 underfloor-heating or irrigation valve zones. Each zone is a plain ZCL on/off endpoint (EP1–EP5). After the Tuya "magic packet" on configure, on/off reporting is bound per endpoint. No Tuya data points are needed.
- Implementation: the device class extends
UnifiedSwitchBasewithgangCount = 5. Capabilities areonoff,onoff.gang2…onoff.gang5, titled "Zone N". - Flow cards (en/fr/nl/de): per zone, triggers
…_gangN_turned_on/off(the naming the runtime trigger heuristics already fire), a condition "zone N is on", and actions on/off/toggle. There is also an "all zones off" action. Actions go throughtriggerCapabilityListener, so the command really reaches the device. - Branch:
prep/new-driver-valve-controller-5zone. Test:test/critical/newdrv-valve-controller-5zone.test.js. - Credit: Zigbee2MQTT / zigbee-herdsman-converters
automaton.ts(Koen Kanters and contributors, PR #5579, zigbee2mqtt #16992); lsroka76/Z2S_Library device database; wonjj6768 SmartThings edge drivers (valves.lua).
remote_rgbcct_8zone — MiBoxer FUT089Z
- Couple (exact only):
_TZ3000_xwh1e22x+TS1002. As you decided, the legacybulb_rgbwentry stays until this driver is published and soaked; after that, a W4 move puts the couple on the remote only. Until then the dual claim is recorded as a reviewed exception indata/native-matrix-reviewed-duals.jsonand in the collision baseline. The pin and registry entry are deliberately postponed to the W4 move, because they would make automation strip thebulb_rgbwentry. - Device: a battery RGB+CCT remote with 8 zones. It does not report state; it sends standard ZCL commands to Zigbee group base+N for zone N (factory base 100, so groups 101–108): onOff on/off, levelControl moveToLevel(WithOnOff), colorControl moveToColorTemperature and moveToHueAndSaturation, plus the Tuya scene command 0xFD on genOnOff.
- Implementation: native only. Battery comes from powerConfiguration. Bound onOff, levelControl and colorControl clusters live in
zone-commands.js. The zone comes from the group id the frame was sent to (meta.groupId); a frame not sent to a group gives zone 0. A settingzone_group_base(default 100) covers remotes whose zones were re-mapped to other groups. - Flow triggers (en/fr/nl/de): on, off, brightness (%), colour temperature (mired + warmth %), colour (hue °, saturation %), scene. Each trigger carries a
zonetoken and a zone dropdown ("any" or 1–8) that the driver filters on. - Open point: we have not yet confirmed that a real Homey receives this remote's group traffic. The library hands the group id to the handlers, but test it on real hardware during the soak, before the W4 move.
- Branch:
prep/new-driver-remote-rgbcct-8zone. Test:test/critical/newdrv-remote-rgbcct-8zone.test.js. - Credit: Zigbee2MQTT
miboxer.ts(FUT089Z zone and group converters; Koen Kanters and contributors); u236/homed-service-zigbee; JohanBendz/com.tuya.zigbee#1361; zigpy/zha-device-handlers#1829. Ledron YK-16 (_TZ3000_zwszqdpy) is the same remote, but it is not added; that needs its own verification.
Johan-only couples — verdicts (2026-10-11)
44 of the 52 Johan-only couples were still unplaced; the other 8 had been placed in the previous round. Rule: we place a couple only when an independent source confirms the same mfr + pid and the same device type. If the second source names a different pid, the Johan couple is not confirmed and nothing is invented.
| Couple | Verdict | Source(s) | Action |
|---|---|---|---|
_TYZB02_key8kk7r TS0043 | 3-button remote | ZHA ts0043 TuyaSmartRemote0043NO; deCONZ Tuya3gangMap | button_wireless_2 → button_wireless_3 |
_TZ3000_rrjr1q0u TS0043 | 3-button remote | deCONZ Tuya3gangMap + wireless switch list | button_wireless_2 → button_wireless_3 |
_TZ3000_mugyhz0q TS0207 | Tuya 899WZ leak sensor | Z2M TS0207_water_leak_detector | water_leak_sensor_tuya → water_leak_sensor |
_TZ3000_0s9gukzt TS0207 | Nous E4 leak sensor | Z2M TS0207_water_leak_detector | water_leak_sensor_tuya → water_leak_sensor |
_TZ3000_zl1kmjqx TS0201 | Temp/humidity sensor | Z2M IH-K009 / RSH-HS06_1; ZHA ty0201 | button_wireless_2 → climate_sensor |
_TZ3000_qeuvnohg TS0121 | not confirmed | Z2M says TS011F DIN relay | none (pid differs) |
_TYZB01_iuepbmpv TS0201 | contradicted | Z2M says TS0121 MS-104Z switch module | none |
_TYZB01_ncutbjdi TS0001/000F/0011 | not confirmed | Z2M says TS0003 1-gang module | none; follow-up: it sits on switch_2_gang |
_TYZB01_aneiicmq TS0001/000F/0011 | not confirmed | Z2M says TS0003 BW-SS7 1-gang | none; same follow-up |
_TZ3210_iystcadi TS0505A | not confirmed | Z2M says TS0505B Lidl light bar | none |
_TZ3210_zxbtub8r TS110F/TS0052 | not confirmed | Z2M says TS110E 1-ch dimmer | none; follow-up: this mfr is on presence_sensor_radar |
_TZ3000_saiqcn0y, _TZ3000_xr3htd96 TS0601 | not confirmed | Z2M/deCONZ say TS0201 | none |
_TZ3000_18ejxno0 TS0042 | not confirmed | Z2M/deCONZ say TS0012 wall switch | none |
_TZ3000_qewo8dlz TS0043 | not confirmed | deCONZ says TS0013 wired 3-gang | none |
| 25 others (TS0042/43/44 buttons, e98krvvk, bagt1e4o, 6oabgtzv, s8r1qoyq, cehuw1lw, dku2cfsc, fjt5218m, 6g8b7at8, vzrytttn) | no second source | — | left as leads |
None of these needed a new driver: every confirmed couple fits an existing one.