Universal Tuya docsHomeSupported devicesRequest a deviceFAQChangelogArchitectureKnowledge baseCreditsSourcesContributing

Issues sweep 2026-10-19 (workstream C2)

Scope: every open issue of dlnraja/com.tuya.zigbee (#571, #570, #560, #559, #557, #550), the recent closed ones (cross-checked for regressions), the Homey diagnostic mails since 17/10, and the forum items collected on 18/10. Nothing was posted, closed or mailed.

IssueWhoCouple / symptomState
#571denis-papinQT-07S _TZE284_myd45weu + TS0601 pairs as unknown, Configure spinnercouple is on soil_sensor on all three trees; the junk productIds that were pruned in P2814 and the settings ready-fallback are published; waiting for a retest on a build >= 9.0.1450
#570edwinvdpAOYAN AY-303Z (plain and two-space padded name) unknown + spinnersame as #571; both name forms and AY-303Z are on soil_sensor everywhere
#560artisareTRV06 _TZE200_rxq4iti9 + TS0601: no battery, phantom humidity, values only on device reportDP35 bit0 -> alarm_battery and humidity strip were on master only; ported to stable-v5 and bastien-home. Two shared root causes found and fixed (below)
#559Lalla80111_TZ3210_w0qqde0g + TS011F plug, no energyalready claimed by plug_energy_monitor on all trees (interview: clusters 0x0702/0x0B04, reporting configured, app version 83) - nothing to change
#557botdaily digestinformational
#550HiepSVG_TZE204_gkfbdvyx radar: lag, ghost alarms, "card unavailable" flickerP2749/P2765/P2796 and the availability flicker guard are on all three trees; open only for the reporter's retest
#554 (closed)draqlekTS0046 _TZ3000_iszegwpd six-button remote refuses pairingmaster and stable had the 4-endpoint fix; bastien-home did not -> ported

Root causes found while reading the #560 diagnostic

  1. tuya.dataQuery never worked with an argument. The command has no payload, but TuyaEF00Manager.requestDP, BaseUnifiedDevice (initial read), TuyaUnifiedDevice (wake) and UnifiedSensorBase (wake) call it with {seq} / {dp}. zigbee-clusters answers unexpected property, so the log line [DATA-QUERY] Completed: 0/12 queries sent is every Tuya DP device at init. Fix P2867: the cluster now always sends the empty query-all frame (cmd 0x03), fire-and-forget, and requestDP sends one query-all per init burst instead of twelve failing calls. Source for the frame: Tuya Zigbee DP protocol (0x03 = gateway asks the device to report all DPs), same command exposed by Zigbee2MQTT / deCONZ.
  2. tuya.datapoint({dp, datatype, data}) without status/transid/length. About 50 call sites (DP36 time sync on TRVs, LCD sensors, purifiers, heaters, the IR blaster) built that bare shape. It does not throw; it writes length 0 next to the payload, a frame the MCU ignores. Fix P2866: the cluster fills only the missing fields; fully specified calls stay byte-identical.
  3. Radiator valve declared onEndDeviceAnnounce() twice. The later one silently won, so the P2598 "re-query DPs when the sleepy valve wakes" path was dead code. Fix P2865: one method, both duties, plus a regression test.

Kept as is (needs a decision)

Checks

← Knowledge base index · source