Field notes — curtain_motor "doesn't move" + mmWave class flip (2026-10-10)

curtain_motor: _TZE200_127x7wnl, _TZE204_5slehgeo, _TZE200_icka1clh

Sources: Homey diagnostics (read-only Gmail, [email removed]), logs ab5aaf04 (01/09, 9.0.775) and the 15-log thread 11/09–13/09 (48baba36 … ed0de063, app 9.0.874–9.0.908); Z2M zigbee-herdsman-converters src/devices/tuya.ts (Koenkk & contributors) for icka1clh.

What the logs show (rewritten, not quoted):

Verdict: every failure pattern in the reports predates fixes already on master, stable-v5 and bastien-home; no report since 13/09. No new runtime change made.

Ask for a new diag if a user reports it again (app ≥ current): the log must show [CURTAIN] P2467 Moes MCU time-sync armed, the P2412/P2464/P2467 Moes ZTS TX line, and 30 s after one Open press whether any DP… received line comes in; plus the device interview (endpoint clusters) and whether the wall button moves the motor. No RX + unreachable = mesh/range; RX but no motion = DP mapping/invert issue.

Open: RX listener fan-out (~6× per frame) on curtain_motor — harmless today, audit later.

mmWave _TZE200_3towulqd class change

Only in presence_sensor_radar (class sensor) on all three branches; device.js refuses any setClass other than sensor (P2548, f509fb2e83, 17/09). Reports through 21/09 are on builds around that fix. Nothing more to change.